Violation Detail
Standard Cited: 19100147 F03 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1799395.015
Citation: 02001C
Citation Type: Willful
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/11/2025
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/07/2025
Gravity: 10
Report ID: 0214200
Contest Date: 08/07/2025
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 08/08/2025 | $0.00 | 08/07/2025 | Willful | |
| Penalty | Z: Issued | 07/11/2025 | $0.00 | 08/07/2025 | Willful |
Text For Citation: 02 Item/Group: 001C Hazard:
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft: a) 1 Eastern Rd, Kearny NJ Multiple employees changed a motor on Ironer #1 with only 1 lock applied to the electrical disconnect. Violation occurred on or about January 24, 2025
Translate