Violation Detail
Standard Cited: 19100335 A02 II Safeguards for personnel protection.
Inspection Nr: 1007955.015
Citation: 02001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/01/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/28/2015
Gravity: 10
Report ID: 0729300
Contest Date: 05/22/2015
Final Order: 12/21/2015
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/21/2015 | $0.00 | 10/28/2015 | Serious | |
Penalty | C: Contested | 05/22/2015 | $0.00 | 06/18/2015 | Willful | |
Penalty | Z: Issued | 05/01/2015 | $0.00 | 06/18/2015 | Willful |
Text For Citation: 02 Item/Group: 001C Hazard:
29 CFR 1910.335(a)(2)(ii): Protective shields, protective barriers, or insulating materials were not used to protect each employee from shock, burns, or other electrically related injuries while that employee was working near exposed energized parts: a/ High frequency testing department (lower level of 4328 Bridgeton Industrial Park Drive, Bridgeton, MO 63044): The employer failed to provide employees with adequate engineering controls while working with live leads during the high frequency testing process.