Violation Detail
Standard Cited: 19100147 C04 II A The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1692501.015
Citation: 02001B
Citation Type: Willful
Abatement Date: 03/14/2024
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/16/2024
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): R
Gravity: 10
Report ID: 0213900
Contest Date: 03/13/2024
Final Order: 03/21/2025
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/21/2025 | $0.00 | 03/14/2024 | Willful | |
Penalty | C: Contested | 04/25/2024 | $0.00 | 03/14/2024 | Willful | |
Penalty | Z: Issued | 02/16/2024 | $0.00 | 03/14/2024 | Willful |
Text For Citation: 02 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(A):The energy control procedures did not contain a specific statement on the intended use of the procedure: a) Worksite was located at 2 Applegate Drive, Robbinsville Twp, NJ 08691: Management did not ensure that lock out tag out procedures were developed for each machine and the lock out tag out procedures needed for the cleaning and servicing process. Procedures were not clear when workers cleaned machines including, but not limited to, the Taeheung Engineering Bag Dump Machine, DHW-32 Mini Wonton Machines and the Gyoza Dumpling Machines. Violation occurred on or about August 20,2023 NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.