Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1502816.015
Citation: 02001B
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/16/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/17/2021
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 05/10/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2021 | $0.00 | 05/17/2021 | Repeat | |
Penalty | Z: Issued | 04/16/2021 | $0.00 | 05/17/2021 | Repeat |
Text For Citation: 02 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about November 17, 2020, employees were exposed to injuries when performing maintenance and servicing on equipment, including but not limited to, the B-13 molding press, and the employer did not certify periodic inspection had been performed. The certification shall include identification of the machine or equipment, the date of the inspection, the employees included in the inspection, and the person performing the inspection. NORTH AMERICAN LIGHTING, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1910.147(C)(6)(I), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1373713 CITATION NUMBER 1, ITEM NUMBER 1B, AND WAS AFFIRMED AS A FINAL ORDER ON MAY 31, 2019, WITH RESPECT TO A WORKPLACE LOCATED AT 2277 S. MAIN ST., PARIS, ILLINOIS, 61944.