Violation Detail
Standard Cited: 19100147 D01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1304388.015
Citation: 02001B
Citation Type: Serious
Abatement Date: 09/28/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/20/2018
Nr Instances: 1
Nr Exposed: 25
Related Event Code (REC): A
Gravity: 10
Report ID: 0830600
Contest Date: 10/11/2018
Final Order: 10/15/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/15/2019 | $0.00 | 09/28/2018 | Serious | |
Penalty | C: Contested | 10/11/2018 | $0.00 | 09/28/2018 | Willful | |
Penalty | Z: Issued | 09/20/2018 | $0.00 | 09/28/2018 | Willful |
Text For Citation: 02 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(1): The authorized employees did not have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy before the authorized or affected employees turned off the machine or equipment: a) SSM Presses: On or about March 23, 2018, and at times prior, workers were not provided with specific information regarding the types and magnitude of hazardous energy, potential hazards and the means to perform a full and effective removal of hazardous energy present in the IDRA and IDRA Prince presses, including Model OL/320 I PRP; Serial No. 7110, such as electrical, mechanical, hydraulic, and pressurized air. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).