Powered by GoogleTranslate

Violation Detail

Standard Cited: 19101025 E01 I Lead.

This violation item has been deleted.

Inspection Nr: 1186795.015

Citation: 02001B

Citation Type: Repeat

Abatement Status:  

Initial Penalty: $0.00

Current Penalty: $0.00

Issuance Date: 03/31/2017

Nr Instances: 2

Nr Exposed: 205

Abatement Date: 04/26/2017

Gravity: 10

Report ID: 0729700

Contest Date: 04/21/2017

Final Order: 09/19/2018

Related Event Code (REC):

Emphasis:

Substance: 1591


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 09/19/2018 $0.00 04/26/2017 Repeat  
Penalty C: Contested 05/04/2017 $0.00 04/26/2017 Repeat  
Penalty Z: Issued 03/31/2017 $0.00 04/26/2017 Repeat  

Text For Citation: 02 Item/Group: 001B Hazard:

29 CFR 1910.1025(e)(1)(i): For any employees exposed to lead above the permissible exposure limit for more than 30 days per year where engineering and work practice controls (including administrative controls) were feasible but did not reduce the employees' exposure to or below the permissible exposure limit the employer did not use engineering and/or work practice controls to reduce exposures to the lowest feasible level: The employer is failing to provide engineering and work practice controls to effectively reduce or minimize the lead exposures in the workplace. This was last observed on November 29, 2016, at 413 E Berg Rd, Salina, Kansas. a) An employee engaged in grid casting activities was exposed to a 12 hour time weighted average (TWA) level of 50.2 ug/m3 of lead, which is 1.5 times the calculated OSHA permissible exposure level (PEL) of 33.3 ug/m3. b) An employee engaged in the COS stacking operations was exposed to a 12 hour TWA level of 289.5 ug/m3 of lead, which is 8.7 times the calculated OSHA permissible exposure level (PEL) of 33.3 ug/m3. Exide Technologies was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1025(e)(1)(i), which was contained in OSHA inspection number 314181025, citation number 2, item number 1b and was affirmed as a final order on August 3, 2011, last abatement date November 30, 2012, with respect to a workplace located at 7471 S. 5th St., Frisco, Texas 75034.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.