Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1122134.015
Citation: 02001B
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/19/2016
Nr Instances: 1
Nr Exposed: 22
Abatement Date: 06/01/2016
Gravity: 10
Report ID: 0317900
Contest Date:
Final Order: 05/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/06/2016 | $0.00 | 06/01/2016 | Willful | |
Penalty | Z: Issued | 04/19/2016 | $0.00 | 05/13/2016 | Willful |
Text For Citation: 02 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. Throughout Shop - on or about February 18, 2016 employees performed servicing and maintenance on machinery with multiple sources of energy to include, but not limited to, the Toyoda FA630 horizontal machining center, Mazak 510 vertical machining center, and the Toyoda FA450 horizontal machining center, but the employer did not provide training to ensure the purpose and function of energy control was understood by all employees.