Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1742402.015
Citation: 02001A
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $38,022.00
Current Penalty: $23,000.00
Issuance Date: 07/11/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/06/2024
Gravity: 1
Report ID: 0627500
Contest Date:
Final Order: 07/23/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/23/2024 | $23,000.00 | 08/06/2024 | Repeat | |
Penalty | Z: Issued | 07/11/2024 | $38,022.00 | 07/26/2024 | Repeat |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.134(f)(2): 29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator is fit tested prior to initial use, whenever a different respirator facepiece (size, style, make or model) is used, and at least annually thereafter. Melt Shop: On or about January 16, 2024, the employer did not ensure that employees utilizing using tight-fitting respirators were fit tested prior to initial use, exposing employees to respiratory hazards. Kyoei Steel (DBA Vinton Steel) was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.134(f)(2), which was contained in OSHA inspection number 1558914, citation number 1, item number 4(a) and was affirmed as a final order on May 4, 2022, with respect to a workplace located at 8001 Border Steel Rd, Vinton Texas, 79821.