Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1684133.015
Citation: 02001A
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $85,938.00
Current Penalty: $47,000.00
Issuance Date: 01/12/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/01/2024
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 02/05/2024
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/05/2024 | $47,000.00 | 04/01/2024 | Repeat | |
| Penalty | Z: Issued | 01/12/2024 | $85,938.00 | 03/01/2024 | Repeat |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. On or about July 14, 2023, the employer did not ensure the developed and documented procedures was utilized for the control of hazardous electrical and hydraulic energy sources of the Dake Bow 2 Vertical Press Machine, while employees were engaged in service and maintenance activities, such as but not limited to, setting up the dies inside the press. Conn-Selmer, Inc., was previously cited for a violation of an equivalent Occupational Safety and Health Standard 1910.147(d), which was contained in OSHA inspection 1345036, Citation 1, Item 2 and was affirmed as a final order on February 27, 2019, with respect to a workplace located at 34199 Curtis Blvd, Eastlake, Ohio.
Translate