Violation Detail
Standard Cited: 19170045 D02 Cranes and derricks (See also 1917.50).
Inspection Nr: 1442903.015
Citation: 02001A
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $79,556.00
Current Penalty: $35,000.00
Issuance Date: 11/29/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/15/2020
Gravity: 5
Report ID: 0420100
Contest Date:
Final Order: 01/07/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/07/2020 | $35,000.00 | 02/15/2020 | Willful | |
Penalty | Z: Issued | 11/29/2019 | $79,556.00 | 12/26/2019 | Willful |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1917.45(d)(2): No crane or derrick having a visible or known defect that affects safe operation shall be used. a) On or about November 6, 2019 on the Manitowoc 3900 and 3500 cranes the foot walk workers used to access the cab and perform inspections did not have handrails/guardrails exposing workers to a fall hazard of approximately 4 foot 11 inches.