Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1431990.015
Citation: 02001A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/05/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 01/24/2020
Gravity:
Report ID: 0830500
Contest Date:
Final Order: 12/23/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/23/2019 | $0.00 | 01/24/2020 | Other | |
| Penalty | Z: Issued | 12/05/2019 | $0.00 | 01/24/2020 | Other |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) California Expanded Metal Products Co. at 490 Osage St. Denver, CO 80204: On and preceding 9/13/19, the employer did not certify that periodic inspections of the energy control procedures had been performed. Maintenance employees participating in Lock Out Tag Out are exposed to inadvertent start up of equipment. The company operates and services equipment such as, but not limited to; LoopCo slitter machine model # D 109-5082 serial # 194SW11457C.