Violation Detail
Standard Cited: 19100147 C02 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1401254.015
Citation: 02001A
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $92,819.00
Current Penalty: $63,000.00
Issuance Date: 11/08/2019
Nr Instances: 1
Nr Exposed: 17
Abatement Date: 11/21/2019
Gravity: 10
Report ID: 0936400
Contest Date:
Final Order: 12/26/2019
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2019 | $63,000.00 | 11/21/2019 | Willful | |
Penalty | Z: Issued | 11/08/2019 | $92,819.00 | 11/21/2019 | Willful |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(2)(ii): The employer's energy control program did not utilize lockout on energy isolating devices capable of being locked out and the employer did not demonstrate that the utilization of a tagout system will provide full employee protection as set forth in 29 CFR 1910.147(c)(3): B Building- Employees performed servicing and maintenance activity such as mold changes on the OCEM Press while it was energized, which exposed employees to injuries from unexpected start-up or energization.