Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1206515.015
Citation: 02001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $126,749.00
Current Penalty: $12,675.00
Issuance Date: 05/22/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/16/2017
Gravity: 10
Report ID: 0111500
Contest Date: 07/11/2017
Final Order: 05/14/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/14/2018 | $12,675.00 | 06/16/2017 | Serious | |
Penalty | C: Contested | 07/13/2017 | $126,749.00 | 06/16/2017 | Willful | |
Penalty | Z: Issued | 05/22/2017 | $126,749.00 | 06/16/2017 | Willful |
Text For Citation: 02 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. Waterbury Location: The employer did not have a specific written procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy for authorized employees during the servicing and maintenance of the Langston Die Cutter. The Master Mechanic was not provided with specific written procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy for the Langston Die Cutter.