Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 998042.015
Citation: 02001
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $30,800.00
Current Penalty: $21,560.00
Issuance Date: 03/18/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/01/2015
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 04/02/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/02/2015 | $21,560.00 | 04/01/2015 | Willful | |
Penalty | Z: Issued | 03/18/2015 | $30,800.00 | 04/01/2015 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Production Building; The employees did not affix lockout or tagout devices to energy isolation devices prior to performing die changes on the 150 ton Cyril Bath Punch Press.