Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100119 D03 II Process safety management of highly hazardous chemicals.

This violation item has been deleted.

Inspection Nr: 663538.015

Citation: 02001

Citation Type: Repeat

Abatement Status:  

Initial Penalty: $38,500.00

Current Penalty: $0.00

Issuance Date: 03/27/2013

Nr Instances: 1

Nr Exposed: 36

Abatement Date: 04/10/2013

Gravity: 10

Report ID: 0627700

Contest Date: 04/17/2013

Final Order: 10/27/2020

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty R: Review Commission 10/27/2020 $0.00 04/10/2013 Repeat  
Penalty C: Contested 04/19/2013 $38,500.00 04/10/2013 Repeat  
Penalty Z: Issued 03/27/2013 $38,500.00 04/10/2013 Repeat  

Text For Citation: 02 Item/Group: 001 Hazard:

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: The employer does not document that equipment in the process complies with recognized and generally accepted good engineering practices. In the Zone 2/CAT Wickes Boiler Area the employer did not ensure it documented the Wickes boiler burner and gas train equipment complied with recognized and generally accepted good engineering practices such as the National Fire Protection Association (NFPA) Standard 85, Boiler and Combustion Systems Hazard Code, and ASME CSD-1, sections CF-310 & CF-330, and ASME Section VI. These practices include, but are not limited to the following equipment: 1. Flame scanner/fire eyes. 2. Automatic pilot gas shutoff valve. 3. Automatic double block (positive shutoff) and automatic bleed on gas train to the burner. 4. Burner management system(s) to control firebox purge, pilot ignition, burner starting, and shutdown. Employees were exposed to fire and explosion hazards from potential releases of fuel gas and other flammable liquids or gasses. WYNNEWOOD REFINING WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIPVALENT STANDARD, 29 CFR 1910.119(d)(3)(ii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER #309785459, CITATION NUMBER #1, Item# 5 AND WAS AFFIRMED AS FINAL ORDER ON AUGUST 4, 2008, WITH RESPECT TO A WORKPLACE LOCATED AT 906 S. POWELL, WYNNEWOOD OK 73098. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure it is documented that the Wickes Boiler burner system compiles with recognized and generally accepted good engineering practices.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.