Violation Detail
Standard Cited: 19100119 D03 II Process safety management of highly hazardous chemicals.
This violation item has been deleted.
Inspection Nr: 663538.015
Citation: 02001
Citation Type: Repeat
Abatement Status:
Initial Penalty: $38,500.00
Current Penalty: $0.00
Issuance Date: 03/27/2013
Nr Instances: 1
Nr Exposed: 36
Abatement Date: 04/10/2013
Gravity: 10
Report ID: 0627700
Contest Date: 04/17/2013
Final Order: 10/27/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 10/27/2020 | $0.00 | 04/10/2013 | Repeat | |
Penalty | C: Contested | 04/19/2013 | $38,500.00 | 04/10/2013 | Repeat | |
Penalty | Z: Issued | 03/27/2013 | $38,500.00 | 04/10/2013 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: The employer does not document that equipment in the process complies with recognized and generally accepted good engineering practices. In the Zone 2/CAT Wickes Boiler Area the employer did not ensure it documented the Wickes boiler burner and gas train equipment complied with recognized and generally accepted good engineering practices such as the National Fire Protection Association (NFPA) Standard 85, Boiler and Combustion Systems Hazard Code, and ASME CSD-1, sections CF-310 & CF-330, and ASME Section VI. These practices include, but are not limited to the following equipment: 1. Flame scanner/fire eyes. 2. Automatic pilot gas shutoff valve. 3. Automatic double block (positive shutoff) and automatic bleed on gas train to the burner. 4. Burner management system(s) to control firebox purge, pilot ignition, burner starting, and shutdown. Employees were exposed to fire and explosion hazards from potential releases of fuel gas and other flammable liquids or gasses. WYNNEWOOD REFINING WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIPVALENT STANDARD, 29 CFR 1910.119(d)(3)(ii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER #309785459, CITATION NUMBER #1, Item# 5 AND WAS AFFIRMED AS FINAL ORDER ON AUGUST 4, 2008, WITH RESPECT TO A WORKPLACE LOCATED AT 906 S. POWELL, WYNNEWOOD OK 73098. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure it is documented that the Wickes Boiler burner system compiles with recognized and generally accepted good engineering practices.