Violation Detail
Standard Cited: 95012901
Inspection Nr: 308546035
Citation: 02001
Citation Type: Serious
Abatement Status: I
Initial Penalty: $2,100.00
Current Penalty: $2,100.00
Issuance Date: 02/02/2006
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/07/2006
Gravity:
Report ID: 0453710
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Text For Citation: 02 Item/Group: 001 Hazard: FALLING
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Falls from unapproved climbing devices such as the "Antenna" a)between the office and production buildings - the local antenna structure which was being used as building roof access only had rungs 3/8" in diameter, had horizontal rung/brace members that were 15 3/8" apart vertically, and only had horizontal brace/rung members that were 8" wide making the structure unapproved for climbing as a ladder for building access. Abatement Note: One means of abatement would be to install a fixed ladder, portable ladder or stair unit for "Retort" building access and egress.