Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1796963.015
Citation: 02001
Citation Type: Repeat
Abatement Status:
Initial Penalty: $25,487.00
Current Penalty: $25,487.00
Issuance Date: 04/16/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/21/2025
Gravity: 10
Report ID: 0522500
Contest Date: 05/15/2025
Final Order:
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 05/16/2025 | $25,487.00 | 05/21/2025 | Repeat | |
Penalty | Z: Issued | 04/16/2025 | $25,487.00 | 05/21/2025 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a. On or about December 18, 2024, an employee performed jam-clearing activities on an Eagle Strip Cutter XD-906Y machine while the equipment was energized and operational. The employer did not ensure that the cutter was disconnected from its electrical energy source prior to performing the servicing activity, thereby exposing the employee to caught-in hazards created from unexpected movement of the machine. Master Magnetics, Inc. was previously cited for a violation of its equivalent Occupational Safety and Health standard 29 CFR 1910.147(c)(1), which was contained in OSHA inspection number 1512903, citation number 1, item number 1, and was affirmed as a final order on April 28, 2021, with respect to a workplace located at 1211 Atchison Court, Castle Rock, CO 80109.