Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1742887.015
Citation: 02001
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $58,076.00
Current Penalty: $58,076.00
Issuance Date: 09/24/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/25/2024
Gravity: 10
Report ID: 0830400
Contest Date:
Final Order: 10/22/2024
Related Event Code (REC): C
Emphasis:
Substance: S777
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/24/2024 | $58,076.00 | 10/25/2024 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). (a)Stone Hill Excavation, LLC at 351 South Douglas Street, Salem, SD 57058: On or about and at times prior to April 22, 2024, the employer did not ensure employees conducting sewer pipe connection and installation within an unprotected excavation greater than five feet in depth were adequately protected from trench wall cave-in. This condition exposed employees to struck-by and cave-in hazards associated with a trench wall collapse.