Violation Detail
Standard Cited: 19100029 F02 Fall protection systems and falling object protection-criteria and practices.
Inspection Nr: 1723587.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/21/2024
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 07/25/2024
Gravity:
Report ID: 0936200
Contest Date: 07/08/2024
Final Order: 06/29/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 06/29/2025 | $0.00 | 07/25/2024 | Other | |
Penalty | C: Contested | 07/10/2024 | $0.00 | 07/25/2024 | Other | |
Penalty | Z: Issued | 06/21/2024 | $0.00 | 07/25/2024 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.29(f)(2): Finger clearance. The employer did not ensure that the minimum clearance between handrails and any other object is 2.25 inches (5.7 cm). Forward end of LCAC 90, access to the LCAC: On and/or before January 25, 2024, employee(s) were accessing the stairs to conduct work on the main deck of the LCAC. The left-hand top rail and mid rail did not provide the minimum clearance for the full length of the rail(s) which did not allow employee(s) to fully grip the railing. Employees were potentially exposed to trip/miss-step and fall hazard(s).