Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1705572.015
Citation: 02001
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $446.00
Current Penalty: $312.20
Issuance Date: 11/27/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/16/2024
Gravity:
Report ID: 0111500
Contest Date:
Final Order: 12/27/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/27/2023 | $312.20 | 01/16/2024 | Repeat | |
| Penalty | Z: Issued | 11/27/2023 | $446.00 | 01/16/2024 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Company: On or about October 24, 2023 the employer had not conducted a documented periodic review of the lockout/tagout procedures for machinery and equipment in the facility. Coherent was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1572848, citation number 3, item number 1 and was affirmed as a final order on April 7, 2022, with respect to a workplace located at 1280 Blue Hills Avenue Bloomfield, CT 06002.