Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1656265.015
Citation: 02001
Citation Type: Willful
Abatement Date: 3
Initial Penalty: $68,754.00
Current Penalty: $20,000.00
Issuance Date: 07/11/2023
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0111400
Contest Date: 08/04/2023
Final Order: 09/19/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/19/2023 | $20,000.00 | Willful | ||
Penalty | C: Contested | 08/16/2023 | $68,754.00 | Willful | ||
Penalty | Z: Issued | 07/11/2023 | $68,754.00 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): Location: Processing Room On or about March 13, 2023, the gears of the dumpling machine in the corner of the processing room furthest from the mixing and grinding room was found to have no guard in place with two employees working in close proximity to the unguarded gears of the forming mold set.