Violation Detail
Standard Cited: 19100253 E05 V Oxygen-fuel gas welding and cutting.
Inspection Nr: 1639786.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/22/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/13/2023
Gravity:
Report ID: 0418600
Contest Date:
Final Order: 03/27/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/27/2023 | $0.00 | 03/13/2023 | Other | |
Penalty | Z: Issued | 02/22/2023 | $0.00 | 03/13/2023 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.253(e)(5)(v): Hose showing leaks, burns, worn places, or other defects rendering it unfit for service were not repaired or replaced: a) Main Shop Area; On or about December 14, 2022, the employer exposed his employees to fire hazard from a damaged oxygen hose attached to an oxygen cylinder in the shop in area on a torch cutting cart.