Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1596294.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/21/2022
Nr Instances: 1
Nr Exposed: 21
Abatement Date: 11/21/2022
Gravity:
Report ID: 0521100
Contest Date:
Final Order: 11/08/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/08/2022 | $0.00 | 11/21/2022 | Other | |
Penalty | Z: Issued | 10/21/2022 | $0.00 | 11/21/2022 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection: On or about May 17, 2022, at the facility located at N1308 Drumlin Drive, Campbellsport, WI, lockout periodic inspections were not documented in 2021 and between January 1, 2022 to May 17, 2022.