Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1576065.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/08/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 07/06/2022
Gravity:
Report ID: 0418100
Contest Date:
Final Order: 07/06/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/08/2022 | $0.00 | 07/06/2022 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: At Pratt (Jet Corr), Inc; on or about February 2, 2022, the employer did not perform an annual periodic inspection of the energy control procedures for the Erhardt Leimer Corrugated GmbH (Skiver) Paper Roll Splicing Machine, S/N S906261, that employees were required to perform maintenance, repairs, services, adjustments, and cleaning.