Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1551976.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $931.00
Current Penalty: $559.00
Issuance Date: 10/18/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/12/2021
Gravity:
Report ID: 0626700
Contest Date:
Final Order: 11/08/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/08/2021 | $559.00 | 11/12/2021 | Other | |
| Penalty | Z: Issued | 10/18/2021 | $931.00 | 11/12/2021 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) The employer did not conduct a periodic inspection of the energy control procedure for a Takisawa CNC machine, model #TT200, serial #TNRW4199, exposing employees to amputation hazards.