Violation Detail
Standard Cited: 19260451 C02 I General requirements.
Inspection Nr: 1529372.015
Citation: 02001
Citation Type: Willful
Abatement Status: Corrected During Inspection
Initial Penalty: $54,613.00
Current Penalty: $33,500.00
Issuance Date: 10/18/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0213400
Contest Date: 09/06/2022
Final Order: 12/28/2022
Related Event Code (REC): I;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/28/2022 | $33,500.00 | Willful | ||
Penalty | C: Contested | 11/28/2022 | $54,613.00 | Willful | ||
Penalty | Z: Issued | 10/18/2021 | $54,613.00 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1926.451(c)(2)(i):Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a. 1650-1660 US 22 East & Vauxhall Rd., Union, NJ - Treasure Island Storage - Union The employer did not ensure that welded tubular frame scaffold was erected in a manner to support the loaded scaffold. Employees engaged in masonry activities worked from a scaffold where the footings were placed on planks supported on blocks that were not capable of supporting the scaffold without settling or displacement. Violation observed on or about May 6, 2021