Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1524740.015
Citation: 02001
Citation Type: Other
Abatement Date: 10/29/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/07/2021
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity:
Report ID: 0523300
Contest Date:
Final Order: 11/02/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/07/2021 | $0.00 | 10/29/2021 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about April 10, 2021, the employer did not conduct a periodic inspection of the energy control procedures for Cooker #1 or Cooker #2 at least annually to ensure the procedure and the requirement of the standard were being followed.