Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1517912.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/29/2021
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/08/2021
Gravity:
Report ID: 0418600
Contest Date:
Final Order: 04/26/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/26/2021 | $0.00 | 04/08/2021 | Other | |
Penalty | Z: Issued | 03/29/2021 | $0.00 | 04/08/2021 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii):The employer�did not�certify that�periodic inspections�of the�energy control�procedures had�been performed: a). Production Floor, on March 3, 2021 and at times prior, the employer failed to document in writing that the machine specific procedures had been certified at least annually for, but not limited to, the Ferracute full revolution mechanical power press #163.