Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1468649.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/02/2020
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 05/31/2022
Gravity:
Report ID: 0627100
Contest Date: 09/29/2020
Final Order: 02/24/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 04/05/2022 | $0.00 | 05/31/2022 | Other | |
Penalty | F: Formal Settlement | 02/24/2021 | $0.00 | 10/01/2020 | Other | |
Penalty | C: Contested | 10/23/2020 | $0.00 | 10/01/2020 | Other | |
Penalty | Z: Issued | 09/02/2020 | $0.00 | 10/01/2020 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about March 13, 2020, the employer did not conduct a periodic inspection for the energy control procedure for 90 ton hydraulic break press labeled P-23. This condition exposed employees who performed setup operations to amputation hazards.