Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1451277.015
Citation: 02001
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $1,082.00
Current Penalty: $757.40
Issuance Date: 03/11/2020
Nr Instances: 7
Nr Exposed: 6
Abatement Date:
Gravity:
Report ID: 0418100
Contest Date:
Final Order: 04/01/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/01/2020 | $757.40 | Other | ||
| Penalty | Z: Issued | 03/11/2020 | $1,082.00 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 12/16/2019, in the pillow production lines one and two at 1720 GA Highway 138, Conyers, GA: A periodic inspection of the energy control procedures for the Pickers, Hoppers, Lapper, and Cut and Roll machines was not conducted at least annually.