Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1374254.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/20/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/08/2019
Gravity:
Report ID: 0317500
Contest Date:
Final Order: 03/06/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/06/2019 | $0.00 | 04/08/2019 | Other | |
| Penalty | Z: Issued | 02/20/2019 | $0.00 | 04/08/2019 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Facility: On or before January 29, 2019, the employer did not conduct a periodic inspection on the implementation of their energy control procedures on equipment such as the Do-All Band Saw at any time in 2018.
Translate