Violation Detail
Standard Cited: 19100179 N03 XI Overhead and gantry cranes.
Inspection Nr: 1359687.015
Citation: 02001
Citation Type: Other
Abatement Date: 06/03/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/26/2019
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC):
Gravity:
Report ID: 0521400
Contest Date:
Final Order: 05/14/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2019 | $0.00 | 06/03/2019 | Other | |
Penalty | Z: Issued | 04/26/2019 | $0.00 | 06/03/2019 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.179(n)(3)(xi): When starting the bridge and when the load or hook approaches near or over personnel, the warning signal shall be sounded: Northeast, grinding department DEMAG 5 Ton C-2 serial no. 94676 and C-4 serial no. 94675 overhead bridge cranes: on or about November 13, 2018, audible alarms were not sounded when starting remote operated bridges to provide advance warnings for personnel working in the area of the moving load's travel path. Abatement documentation is required for this item in accordance with the requirement of 29 CFR 1903.19(d).