Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1346632.015
Citation: 02001
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $20,420.00
Current Penalty: $17,357.00
Issuance Date: 02/15/2019
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 03/29/2019
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 03/05/2019
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/05/2019 | $17,357.00 | 03/29/2019 | Repeat | |
Penalty | Z: Issued | 02/15/2019 | $20,420.00 | 02/27/2019 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: (a) Sawmill, canter/chip and saw (CNS) line; On or about September 13, 2018, energy isolation was not used while blocked photo eyes were being cleared on the canter/chip and saw (CNS) line. The Biewer-Wisconsin Sawmill, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1238126, citation number 1, item number 1b and was affirmed as a final order on November 28, 2017 with respect to a workplace located at 400 Red Pine Court, Prentice, WI 54556.