Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1278555.015
Citation: 02001
Citation Type: Willful
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $71,135.00
Current Penalty: $20,000.00
Issuance Date: 04/27/2018
Nr Instances: 1
Nr Exposed: 28
Abatement Date: 06/16/2018
Gravity: 10
Report ID: 0317900
Contest Date:
Final Order: 05/21/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/21/2018 | $20,000.00 | 06/16/2018 | Willful | |
Penalty | Z: Issued | 04/27/2018 | $71,135.00 | 05/16/2018 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) 1101 Koffel Rd. Hatfield, PA - on or about November 21, 2017, employees perform servicing and maintenance of equipment to include but not limited to, servicing and cleaning of ovens, meat grinders, and blenders. The employer did not implement and require procedures be followed to turn off or shut down machines and equipment.