Violation Detail
Standard Cited: 19100095 C01 Occupational noise exposure.
Inspection Nr: 1275328.015
Citation: 02001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,195.00
Current Penalty: $7,920.00
Issuance Date: 04/16/2018
Nr Instances: 2
Nr Exposed: 12
Abatement Date: 10/05/2018
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 05/08/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/08/2018 | $7,920.00 | 10/05/2018 | Serious | |
Penalty | Z: Issued | 04/16/2018 | $12,195.00 | 06/05/2018 | Serious |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average (TWA) sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: Menard, Inc.; The employer did not implement a continuing and effective hearing conservation program when employees were exposed to noise levels equal to or exceeding the 8-hour time-weighted average sound level of 85 decibels. (a) Building 34; An employee operating the Hitachi saw (C12FDH) was exposed to continuous noise levels exceeding an 8-hour time-weighted average (TWA) of 85 dBA during the 470 minute sampling period conducted on November 30, 2017. The employee's 8-hour TWA noise dose was 85.32% which is equivalent to approximately 88.8 dBA. Zero exposure was assumed for the unsampled time period of 10 minutes. (b) Building 10; An employee working at the Pallet Up-Ender station was exposed to continuous noise levels exceeding an 8-hour time-weighted average (TWA) of 85 dBA during the 467 minute sampling period conducted on January 18, 2018. The employee's 8-hour TWA noise dose was 96.25% which is equivalent to approximately 89.7 dBA. Zero exposure was assumed for the unsampled time period of 13 minutes.