Violation Detail
Standard Cited: 19100213 R04 Woodworking machinery requirements.
Inspection Nr: 1247394.015
Citation: 02001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $114,074.00
Current Penalty: $12,934.00
Issuance Date: 09/06/2017
Nr Instances: 3
Nr Exposed: 4
Abatement Date: 09/25/2017
Gravity: 10
Report ID: 0626600
Contest Date: 10/03/2017
Final Order: 03/25/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 03/25/2019 | $12,934.00 | 09/25/2017 | Serious | |
Penalty | C: Contested | 10/03/2017 | $114,074.00 | 09/25/2017 | Willful | |
Penalty | Z: Issued | 09/06/2017 | $114,074.00 | 09/25/2017 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.213(r)(4): Suitable guard(s) and exhaust hood(s) were not provided to reduce to a minimum the hazard due to the point of operation of a cutoff (jump) saw. a. On or about July 13, 2017, in the Cutback Area, where employees were exposed to a struck-by hazard while operating a Whirlwind Cutoff Saw, Model 212, ID #3 to cut wood without a suitable guard and exhaust hood. b. On or about July 13, 2017, and times prior thereto, in the Cutback Area, where employees were exposed to a struck-by hazard while operating a Whirlwind Cutoff Saw, Model 212, ID #1 to cut wood without a suitable guard and exhaust hood. c. On or about July 13, 2017, and times prior thereto, in the Cutback Area, where employees were exposed to a struck-by hazard while operating a Whirlwind Cutoff Saw, Model 212, ID #2 to cut wood without a suitable guard and exhaust hood.