Violation Detail
Standard Cited: 19260501 B11 Duty to have fall protection.
Inspection Nr: 1132269.015
Citation: 02001
Citation Type: Willful
Abatement Status: Corrected During Inspection
Initial Penalty: $35,000.00
Current Penalty: $20,000.00
Issuance Date: 06/24/2016
Nr Instances: 1
Nr Exposed: 8
Abatement Date:
Gravity: 10
Report ID: 0213600
Contest Date:
Final Order: 07/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/06/2016 | $20,000.00 | Willful | ||
Penalty | Z: Issued | 06/24/2016 | $35,000.00 | Willful |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 3/14/16 at a residential construction project located at 61 John Alex Drive, West Seneca, New York; employees were installing shingles on the roof of a 1 story house with a 7 in 12 roof pitch and an eave height of up to approximately 15 feet. There was no fall protection in use. NO CERTIFICATION ABATEMENT REQUIRED