Violation Detail
Standard Cited: 19100095 B01 Occupational noise exposure.
Inspection Nr: 1131016.015
Citation: 02001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $50,000.00
Current Penalty: $9,000.00
Issuance Date: 07/29/2016
Nr Instances: 9
Nr Exposed: 11
Abatement Date: 01/09/2019
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/23/2016
Related Event Code (REC):
Emphasis:
Substance: 8110
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/23/2016 | $9,000.00 | 01/09/2019 | Serious | |
Penalty | Z: Issued | 07/29/2016 | $50,000.00 | 11/09/2016 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized: a) In the Pattern Cleaning area of Plant 2, a Pattern Cleaner employee was exposed to noise at 1631% (noise dose) of the allowable noise dose of 100% during a sample period of 445 minutes during one shift on March 30, 2016. 1631% is equivalent to an 8-hour TWA sound level of 110.1 dBA. b) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1567.2% (noise dose) of the allowable noise dose of 100% during a sample period of 489 minutes during one shift on March 31, 2016. 1567.2% is equivalent to an 8-hour TWA sound level of 109.8 dBA. c) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1712.2% (noise dose) of the allowable noise dose of 100% during a sample period of 476 minutes during one shift on March 31, 2016. 1712.2% is equivalent to an 8-hour TWA sound level of 110.4 dBA. d) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1777.0% (noise dose) of the allowable noise dose of 100% during a sample period of 480 minutes during one shift on March 31, 2016. 1777.0% is equivalent to an 8-hour TWA sound level of 110.7 dBA. e) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1785.2% (noise dose) of the allowable noise dose of 100% during a sample period of 484 minutes during one shift on March 31, 2016. 1785.2% is equivalent to an 8-hour TWA sound level of 110.8 dBA. f) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1621.6% (noise dose) of the allowable noise dose of 100% during a sample period of 485 minutes during one shift on March 31, 2016. 1621.6% is equivalent to an 8-hour TWA sound level of 110.1 dBA. g) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 2030.3% (noise dose) of the allowable noise dose of 100% during a sample period of 471 minutes during one shift on March 31, 2016. 2030.3% is equivalent to an 8-hour TWA sound level of 111.7 dBA. h) In the Shakeout area of Plant 3, a Shakeout employee was exposed to noise at 1872.7% (noise dose) of the allowable noise dose of 100% during a sample period of 473 minutes during one shift on March 21, 2016. 1872.7% is equivalent to an 8-hour TWA sound level of 111.1 dBA. i) In the Pattern Cleaning area of Plant 3, a Pattern Cleaner employee was exposed to noise at 792.1% (noise dose) of the allowable noise dose of 100% during a sample period of 490 minutes during one shift on May 4, 2016. 792.1% is equivalent to an 8-hour TWA sound level of 104.9 dBA. Applicable administrative or engineering controls may include, but are not limited to the following: 1. Conduct thorough noise studies in the Pattern Cleaning Areas (Plant 2 and Plant 3) and the Shakeout shacks (Plant 3) to verify noise sources, source noise frequencies, reflective surfaces and employee operations/positions for most effective engineering controls. 2. Pattern Cleaning (Plant 2 and Plant 3) i) Enclose the abrasive blasting of patterns and isolate the Pattern Cleaner employee from the noise generated during the abrasive blasting of patterns. ii) Relocate or redesign the Pattern Cleaning areas by eliminating or reducing the reflective surfaces, such as the cinderblock walls and low metal ceiling, in order to reduce the reverberant noise generated during the abrasive blasting of patterns. iii) Institute employee rotation or limit individuals' time at Pattern Cleaning to reduce the amount of time the operator is exposed to noise generated during abrasive blasting of patterns. 3. Shakeout i) Minimixe (to the extent possible) the fall height of castings at the transition from the high frequency screens to the sorting tables. ii) Line the underside of the sorting tables with damping material. iii) Increase the distance between employees and the high frequency screen. iv) Isolate the Shakeout employees from the noise generated by the high frequency screens and sorting tables. The Waupaca Foundry, Inc. (Plant 1) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.95(b)(1), which was contained in OSHA inspection number 1052486, citation number 1, item number 1 and was affirmed as a final order on October 2, 2015, with respect to a workplace located at 406. Division Street, Waupaca, WI 54981. The Waupaca Foundry, Inc. (Plant 1) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.95(b)(1), which was contained in OSHA inspection number 940732, citation number 1, item number 1 and was affirmed as a final order on March 7, 2014, with respect to a workplace located at 406 N. Division Street, Waupaca, WI 54981.