Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1120455.015
Citation: 02001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $6,300.00
Issuance Date: 03/28/2016
Nr Instances: 2
Nr Exposed: 16
Abatement Date: 04/21/2016
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 04/22/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 03/28/2016 | $6,300.00 | 04/21/2016 | Serious |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Building 26, seed sorting area. On January 21, 2016 at times prior thereto employees were exposed to unguarded rotating horizontal drive shafts while cleaning under the equipment. Note: Abatement certification and documentation are required for is item.