Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 110224.015
Citation: 02001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $20,000.00
Current Penalty: $7,000.00
Issuance Date: 01/27/2012
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 03/12/2012
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 02/23/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/23/2012 | $7,000.00 | 03/12/2012 | Serious | |
| Penalty | Z: Issued | 01/27/2012 | $20,000.00 | 03/12/2012 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about December 5, 2011, the employer did not ensure that employees were protected from unguarded end shafts while working with and near the tortilla lines (conveyors, mixiers) in the following areas: 1) # 2 Machine 2) Tortilla Machine near plastic ties. 3) # 2 Chip Mixer 4) Chip Machine (north-end of building) 5) Salter Conveyor