Violation Detail
Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1083240.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/02/2015
Nr Instances: 2
Nr Exposed: 17
Abatement Date: 10/14/2015
Gravity:
Report ID: 0522500
Contest Date:
Final Order: 10/26/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/26/2015 | $0.00 | 10/14/2015 | Other | |
Penalty | Z: Issued | 10/02/2015 | $0.00 | 10/14/2015 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection shall be conducted to correct any deviations or inadequacies identified. a. Located at 100 East Broadway Street in Jackson, Ohio: the employer did not ensure that an annual periodic inspection of the energy control procedure for Extruder 15 was conducted to identify kinetic energy stored at the screw drive. b. Located at 100 East Broadway Street in Jackson, Ohio: the employer did not ensure that an annual periodic inspection of the energy control procedure for Extruder 16 was conducted to identify kinetic energy stored at the screw drive.