Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1075270.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $1,000.00
Current Penalty: $1,000.00
Issuance Date: 12/28/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/30/2016
Gravity:
Report ID: 0830300
Contest Date:
Final Order: 01/06/2016
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/06/2016 | $1,000.00 | 01/30/2016 | Other | |
| Penalty | Z: Issued | 12/28/2015 | $1,000.00 | 01/30/2016 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) For employees exposed to caught-in hazards where servicing activity were performed on equipment including but not limited to the asphalt slat conveyor while in operation approximately four miles northwest of Harold, South Dakota.