Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1036511.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/20/2015
Nr Instances: 9
Nr Exposed: 2
Abatement Date: 04/24/2015
Gravity:
Report ID: 0336000
Contest Date:
Final Order: 04/13/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/13/2015 | $0.00 | 04/24/2015 | Other | |
| Penalty | Z: Issued | 03/20/2015 | $0.00 | 04/24/2015 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The certification did not identify the person performing the inspection: A.) Zurn Industries, LLC, 1801 Pittsburgh Avenue, Erie, PA 16502, on or about February 6, 2015 and times prior thereto: Employees perform lockout/tagout on equipment including, but not limited to, the Hitachi Seiki 2201 and 2202 Vertical CNC machines, for service and maintenance. The lockout procedure review and verification form did not identify the person performing the periodic inspection.