Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 314767104
Citation: 01039B
Citation Type: Serious
Abatement Date: 03/31/2011 X
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/14/2011
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC):
Gravity: 05
Report ID: 0625700
Contest Date: 04/04/2011
Final Order: 04/11/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 03/14/2011 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 039B Hazard: REFINERY
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified at 29 CFR 1910.219(m) & (o): The employer does not ensure employees are protecte d from contact with unguarded pulleys. The unguarded pulley was on a motor power ing a wall-mounted ventilation fan. Employee(s) were exposed to a caught-between hazard. This violation was observed on or about September 20, 2010. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including the steps that it is taking to ensure that employees are not being exposed to unguarded pulleys.