Violation Detail
Standard Cited: 19100179 J02 III Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 314767104
Citation: 01038B
Citation Type: Serious
Abatement Date: 03/31/2011 X
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/14/2011
Nr Instances: 3
Nr Exposed: 12
Related Event Code (REC):
Gravity: 10
Report ID: 0625700
Contest Date: 04/04/2011
Final Order: 04/11/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/26/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/14/2011 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 038B Hazard: REFINERY
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with signed reports, w ere not performed: a) The employer does not ensure that crane hooks are inspecte d, and the inspection certified, on a monthly basis. A five ton overhead crane in the maintenance shop was used to move large pieces and/or equipment to work on. This violation was d ocumented on or about September 20, 2010. b) The employer does not ensure that c rane hooks are inspected, and the inspection certified, on a monthly basis. A on e ton Duff Lynx overhead crane in the pump shop was used to position pumps being repaired. This violation was documented on or about September 20, 2010. c) The employer does not ensure that crane hooks are inspected, and the inspection cert ified, on a monthly basis. A one ton Dayton overhead crane in the outside storag e area was used to move stored materials. This violation was documented on or ab out September 20, 2010 in the maintenance yard. Pursuant to 29 C.F.R. 1903.19, w ithin ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in comp liance with the standard, including the steps that it is taking to ensure that e mployees are not being exposed to struck-by hazards while operating the overhead crane.