Violation Detail
Standard Cited: 19100179 B05 Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 314767104
Citation: 01038A
Citation Type: Serious
Abatement Status: X
Initial Penalty: $5,000.00
Current Penalty: $0.00
Issuance Date: 03/14/2011
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 03/31/2011
Gravity: 10
Report ID: 0625700
Contest Date: 04/04/2011
Final Order: 04/11/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/26/2018 | $0.00 | Serious | ||
| Penalty | Z: Issued | 03/14/2011 | $5,000.00 | Serious |
Text For Citation: 01 Item/Group: 038A Hazard: REFINERY
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: The employer does not ensure that overhead cranes are plainl y marked with the rated load. The five-ton overhead crane in the maintenance sho p was not plainly marked with its rated load. This violation was observed on Sep tember 20, 2010. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of th e date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including the steps that it is taking to ens ure that employees are not being exposed to struck-by hazards while operating th e overhead crane.ad