Violation Detail
Standard Cited: 19101026 D01
Inspection Nr: 1692701.015
Citation: 01032
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,452.00
Current Penalty: $6,452.00
Issuance Date: 02/20/2024
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 03/19/2024
Gravity: 10
Report ID: 0418200
Contest Date: 03/15/2024
Final Order: 09/11/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/11/2024 | $6,452.00 | 03/19/2024 | Serious | |
Penalty | C: Contested | 03/21/2024 | $6,452.00 | 03/19/2024 | Serious | |
Penalty | Z: Issued | 02/20/2024 | $6,452.00 | 03/19/2024 | Serious |
Text For Citation: 01 Item/Group: 032 Hazard:
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) Production Area- Hexavalent Chrome Tank; On or about August 22, 2023, and at times prior, the employer exposed employees to hexavalent chromium hazards, in that an employee was batching chromium phosphate and was exposed to hexavalent chromium at an 8-hour TWA of 0.0186 mg/m3. This level exceeded the permissible exposure level (PEL) of 0.005 mg/m3 by 3.8 times. The exposure was derived from a sample collected for a 470-minute sampling period. Exposure calculations included a zero increment for the time not sampled. b) Production Area- Hexavalent Chrome Tank; On or about August 22, 2023, and at times prior, the employer exposed employees to hexavalent chromium hazards, in that an employee was batching chromium phosphate and was exposed to hexavalent chromium at an 8-hour TWA of 0.0139 mg/m3. This level exceeded the permissible exposure level (PEL) of 0.005 mg/m3 by 2.8 times. The exposure was derived from a sample collected for a 478-minute sampling period. Exposure calculations included a zero increment for the time not sampled.