Violation Detail
Standard Cited: 19100261 A03 I Pulp, paper, and paperboard mills.
Inspection Nr: 1207843.015
Citation: 01030
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,605.00
Current Penalty: $3,650.00
Issuance Date: 06/26/2017
Nr Instances: 9
Nr Exposed: 46
Abatement Date: 04/03/2018
Gravity: 5
Report ID: 0215800
Contest Date: 07/09/2017
Final Order: 02/02/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/02/2018 | $3,650.00 | 04/03/2018 | Serious | |
Penalty | C: Contested | 07/26/2017 | $7,605.00 | 07/07/2017 | Serious | |
Penalty | Z: Issued | 06/26/2017 | $7,605.00 | 07/07/2017 | Serious |
Text For Citation: 01 Item/Group: 030 Hazard:
29 CFR 1910.261(a)(3)(i): Industrial lighting was not in accordance with American National Standards Institute (ANSI) Practice for Industrial Lighting, A11.1 - 1965 (R-1970), which is incorporated by reference as specified in 29 CFR 1910.6: a) On or about 2/7/2017, Compressor Room: The stair way from the compressor room to the basement was not provided with adequate lighting as there were only 2 foot candles of light present. b) On or about 2/7/2017, Basement main walk way: The majority of the main walk way in the basement was not provided with adequate lighting as there were only 2.8 foot candles of light present. c) On or about 2/7/2017, Basement, work areas on either sides of the main walk way: The work areas on either side of the main walk way were provided with adequate lighting as there was less than 1 foot candle of light present. d) On or about 2/15/2017, Wet end of paper machine: The drive side was not provided with adequate lighting as there was only 2 foot candles of light present. e) On or about 2/15/2017, Stairs to basement by roll splitter: The stairs to the basement by the roll splitter were not provided with adequate lighting as there was less than 1 foot candle of light present. f) On or about 2/15/2017, Generator room: The generator room was not provided with adequate lighting as there was only 1.5 foot candles of light present. g) On or about 2/15/2017, Beater area: The beater pulper pulpit was not provided with adequate lighting as there was less than 2 foot candles of light present. h) On or about 2/15/2017, Beater area: The stairs to the second floor near the beater area break room were not provided with adequate lighting as there was less than 1 foot candle of light present. i) On or about 2/15/2017, Store room area: The main exit and access for the facility referred to as the store room exit was not provided with adequate lighting as there was only 0.1 foot candles of light present on the outside and only 0.3 foot candles of light present on the inside of the exit. Abatement certification is required for these items.