Standard Cited: 19100119 L01 Process safety management of highly hazardous chemicals.

Inspection Nr: 311917009

Citation: 01025

Citation Type: Serious

Abatement Status: X

Initial Penalty: $5,000.00

Current Penalty: $5,000.00

Issuance Date: 05/13/2009

Nr Instances: 9

Nr Exposed: 11

Abatement Date: 06/29/2009

Gravity: 10

Report ID: 0213400

Contest Date: 06/03/2009

Final Order: 12/24/2009

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty R: Review Commission 12/24/2009 $5,000.00 06/29/2009 Serious  
Penalty J: ALJ Decision 08/28/2009 $5,000.00 06/29/2009 Serious  
Penalty Z: Issued 05/13/2009 $5,000.00 06/29/2009 Serious  

Text For Citation: 01 Item/Group: 025 Hazard: REFINERY

29 CFR 1910.119(l)(1): The employer did not establish and implement written procedures to manage changes to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process: c- Hess Port Reading Refinery, FCCU - An MOC was not written to allow T-501 to operate with cementitious fireproofing missing from pipe support tie-ins found on the tower's skirt. Condition noted on or about 02/27/09. d- Hess Port Reading Refinery, Alky - An MOC was not written to allow T-703 to operate with cementitious fireproofing removed from the upper circumference of the skirt. Condition noted on or about 02/27/09. e- Hess Port Reading Refinery, Alky - An MOC was not written for the use of a temporary pipe support for a 6 inch overhead line on E-711C. Conditions noted on or about 02/27/09. f- Hess Port Reading Refinery, FCCU - An MOC was not written for a temporary pipe support on an insulated line on top of T-503 Naphtha Splitter. Condition noted on or about 02/27/09. g- Hess Port Reading Refinery, SRU - An MOC was never written when a check valve was installed on the MEA acid gas bypass line. On 02/28/08 this check valve failed allowing hydrogen sulfide to back flow through the line and overcome an operator. Condition noted on or about 02/06/09. h- Hess Port Reading Refinery, Gas Con - An MOC was not written for the "Arkansas Cooler" used on the E-635A/B/C Debutanizer Bottoms Cooler on or about 01/05/09.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.