Violation Detail

Standard Cited: 19100119 J05 Process safety management of highly hazardous chemicals.

Inspection Nr: 311917009

Citation: 01024

Citation Type: Serious

Abatement Status: X

Initial Penalty: $5,000.00

Current Penalty: $5,000.00

Issuance Date: 05/13/2009

Nr Instances: 10

Nr Exposed: 10

Abatement Date: 06/29/2009

Gravity: 10

Report ID: 0213400

Contest Date: 06/03/2009

Final Order: 12/24/2009

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty R: Review Commission 12/24/2009 $5,000.00 06/29/2009 Serious  
Penalty J: ALJ Decision 08/28/2009 $5,000.00 06/29/2009 Serious  
Penalty Z: Issued 05/13/2009 $5,000.00 06/29/2009 Serious  

Text For Citation: 01 Item/Group: 024 Hazard: REFINERY

29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment paragraph (d)) before further use or in a safe and timely manner: a- Hess Port Reading Refinery, FCCU - Cementitious fireproofing was removed and not replaced on the T-501 Main Column when steel pipe supports were connected to the tower's skirt. Condition noted on or about 02/27/09. b- Hess Port Reading Refinery, FCCU - Motor operated valves (MOVs) for the P- 518A/B Main Column Bottoms Pump and associated electrical conduit was not fireproofed. Condition noted on or about 12/15/08. c- Hess Port Reading Refinery, FCCU - Cementitious fireproofing had fallen from a section of structural steel above E-510 LCO Product/Raw Oil Exchanger leaving a section of the steel unprotected. Condition noted on or about 12/16/08. d- Hess Port Reading Refinery, Alky - Cementitious fireproofing had been removed from the upper skirt of the T-703 Debutanizer spanning the tower's entire circumference. Condition noted on or about 02/27/09. e- Hess Port Reading Refinery, Dimersol - The RD for P-2202A 2nd Reactor Pump Around had burst as indicated by a reading of 350 psi on the tell tale pressure gauge. Condition noted on or about 03/05/09. f- Hess Port Reading Refinery, Dimersol - The tell tale pressure gauge for S-2202B Caustic Rag Filter was reading 14 psi indicating a potential leak through the RD. Condition noted on or about 03/05/09. h- Hess Port Reading Refinery, Alky - The snuffing steam line for P-701B Effluent Recycle Pump was not installed properly. The pipe outlet was not pointed at the pump seal making it ineffective in extinguishing a potential seal fire. Condition noted on or about 02/27/09. i- Hess Port Reading Refinery, FCCU - The P-506B LCO Circulating Pump was operated with a bent and damaged grounding wire. Condition noted on or about 12/15/08. j- Hess Port Reading Refinery, Gas Con - The D-609 Lean Gas Knock Out Drum RV Bypass High Point Vent was missing a gasket and the flange was improperly secured with bolts missing their nuts. Condition noted on or about 12/18/08. k- Hess Port Reading Refinery, Gas Con - The pressure gauge for the P-602B Stripper Charge Pump was inoperative with a reading 600 psi. Condition noted on or about 12/18/08.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.